Environmental Control Center Six-Outlet Terrarium Automation System for Reptiles
Product Description
Zoo Med Environmental Control Center automates your reptile terrarium with a single six-outlet unit that manages heat dimming, heating or cooling on/off, humidity, and three timers for lighting and other devices. Two temperature probes and a humidity probe feed a wired LCD remote, where you program day and night settings, alarms, and natural temperature drops.
Benefits
- Six Outlets, One Controller: Manages dimming heat, heating or cooling, humidity, and three timers from a single six-outlet unit.
- Adjustable Heat Output: Socket 1 regulates heat output by gradually dimming sources such as incandescent bulbs to maintain the set temperature.
- Heat or Cool Mode: Socket 2 runs heaters in Heat mode or cooling devices, such as fans, in Cool mode.
- Humidity Control: Socket 3 turns a mister or fogger on to humidify the enclosure, or a fan on to dehumidify it.
- Built-In Timers: Socket 4 offers two on/off periods, while Sockets 5 and 6 alternate as day and night timers.
- Day and Night Settings: Program separate daytime and nighttime temperatures to create natural temperature fluctuations and nighttime drops, per Zoo Med.
- High and Low Alerts: Visual and audible alarms activate when the terrarium temperature or humidity reaches the set high or low limit.
- Wide Device Compatibility: Zoo Med lists compatibility with incandescent, mercury vapor, fluorescent, halogen, and LED lamps, as well as heaters, misters, and foggers.
- Settings Memory: Built-in memory saves your settings if power fails, though the clock must be reset afterward.
Specifications
| Specification | Details |
|---|---|
| Total load | Up to 1000 watts combined |
| Maximum per socket | Socket 1: 400 watts; Socket 2: 550 watts; Socket 3: 100 watts; Sockets 4, 5, and 6: 400 watts each |
| Outlets | 6 |
| Probes | 2 temperature probes and 1 humidity probe, each with a 3-meter (9-foot) lead |
| Daytime temperature range | 36 to 140 degrees Fahrenheit (2 to 60 degrees Celsius) |
| Nighttime temperature range | 36 to 104 degrees Fahrenheit (2 to 40 degrees Celsius) |
| Humidity range | 15 to 95% relative humidity |
| Memory | Stores settings in case of power failure; time of day must be reset |
| Alarm | Flashes and beeps at extreme high or low temperature or humidity |
| Handset | Wired LCD remote; connects with the included auxiliary cable |
| Default settings | Sockets 1 and 2: 86 degrees Fahrenheit day, 70 degrees Fahrenheit night; Socket 3: 60% day, 50% night |
| Power | 120-volt, 60-hertz grounded outlet |
| Includes | Controller unit, controller stand, LCD remote control, remote wall mount, 2 temperature probes, 1 humidity probe |
| Use | Indoor use only |
| Warranty | 1 year |
How to Use
Recommended Usage Chart
| Socket | Function | Example Devices |
|---|---|---|
| Socket 1 | Dimming heat, monitored by Temperature Probe 1 | Incandescent bulb, ceramic heat emitter |
| Socket 2 | On/off heating or cooling, monitored by Temperature Probe 2 | Heat lamps, under tank heaters, ceramic heat emitters, fans |
| Socket 3 | Humidify or dehumidify, monitored by the Humidity Probe | Misters, foggers, fans |
| Socket 4 | Digital timer with two on/off periods | UVB lights, LED lighting, misting machines |
| Socket 5 | Day timer | Daytime heat lamp or lighting |
| Socket 6 | Night timer | Nighttime heat lamp |
Disclaimer: Product information and usage guidelines are provided by the manufacturer. Always use products as directed and consult your vet for any queries regarding your pet’s well-being.
Usage Instructions
- Charge the Handset: Remove the plastic tab from the handset's battery compartment to charge the battery before programming.
- Program Before Installing: Plug in the unit and program your settings first; wait until programming is done before connecting devices.
- Set the Clock: Use the clock button to program the daytime and nighttime start times, followed by the current time.
- Program Dimming Heat (Socket 1): Use the socket, row, and arrow buttons to set day and night temperatures and the alarm.
- Program Heat or Cool (Socket 2): Choose Heat or Cool, set day and night temperatures, the Diff value, and the alarm.
- Program Humidity (Socket 3): Choose Humi or Dehumi, then set the day and night humidity levels, the Diff value, and the alarm.
- Set the Timers (Sockets 4 to 6): Program Socket 4's two on/off periods, then set the on times for Sockets 5 and 6.
- Install the Probes: Place the temperature and humidity probes inside the terrarium using double-sided tape or hook-and-loop fastener.
- Mount the Control Unit Outside: Position the controller outside the terrarium, as higher temperatures and humidity can cause it to fail inside the terrarium.
- Connect Your Devices: Plug heaters or coolers into Heating or Cooling, humidifiers into Humidify/Dehumidify, and remaining equipment into the timer sockets.
- Switch Devices On: Make sure each heating cooling, and humidifying device is switched on so the controller can run it.
Additional Information
Precautions
- Wattage Limits: Stay within each socket's maximum wattage and the unit's total load; never overload it.
- Socket 1 Restrictions: Do not use the dimming socket to control mercury vapor UVB lamps, compact fluorescent lamps, or rock heaters.
- No Rock Heaters: The unit is not designed to control rock heater temperature; Zoo Med recommends its rheostat instead.
- Grounded Outlet Only: Plug only into a 120-volt, 60-hertz grounded outlet; never use a two-prong adapter.
- Keep Components Dry: Only the two temperature probes may be placed in water; never immerse any other component.
- Controller and Handset Outside: Keep the controller and handset outside cages and terrariums; only the remote sensors go inside.
- Protect Cords: Never stretch wires, rest heavy objects on cords, operate a damaged unit, or alter the plug.
- Fire Safety: Do not block UVB lamps or place flammable materials close to heating devices in or around the terrarium.
- Sensor Placement: Keep sensors away from heating or cooling devices so they read the correct temperature gradient and humidity.
- Indoor Use Only: The Environmental Control Center is for indoor use only and should not be used outdoors.
Storage Information
- Unplug Everything: Unplug all connected devices and the controller before moving or storing the system for safety.
- Store Dry and Indoors: Coil the probe leads loosely and keep all components together in a cool dry indoor place.
Shipping & Return
We offer ground, express, priority, and international delivery; see our shipping policy for details.
For return instructions or product concerns, please refer to our detailed refund policy.
Frequently Asked Questions
Q1: What is a reptile environmental controller?
Ans: It is a single unit that automates heating, cooling, humidity, and lighting. Zoo Med's Environmental Control Center does this through six outlets: a dimming heat socket, a heat-or-cool socket, a humidity socket, and three timer sockets, all programmed from a single remote.
Q2: Can it control a mercury vapor UVB bulb?
Ans: Zoo Med lists mercury vapor lamps among compatible devices, but they must not be connected to Socket 1, the dimming socket. Run a mercury vapor UVB lamp from a timer socket instead, staying within that socket's 400-watt maximum listed in the specifications.
Q3: Is the remote wireless?
Ans: No. Zoo Med confirms the handset is not wireless. It must be plugged into the control center using the provided auxiliary cable to change your settings, and Zoo Med recommends keeping the handset and controller outside the terrarium.
Q4: How do I set a nighttime temperature drop?
Ans: After setting the daytime temperature for Socket 1 or 2, press the row button until Night Set blinks, then use the arrows to choose your nighttime temperature. The clock settings decide when the controller switches between day and night periods.
Q5: Why is my controller showing an error code?
Ans: EE means a sensor failure or the range was exceeded, LL means an extremely low temperature, HH means an extremely high reading and HF means an extremely high temperature on the dimming socket. Check that sensors are not too close to heat sources or submerged.
Q6: Why isn't my terrarium reaching the set temperature or humidity?
Ans: Zoo Med notes your heating device must be able to reach the desired temperature, so you may need a higher-wattage heater. Humidity also changes with ventilation; covering part of a screen top with a suitable material can help some terrariums hold humidity.
Q7: Will I lose my settings if the power goes out?
Ans: No. Built-in memory stores your programmed settings and resumes them once power is restored. However, Zoo Med notes the time of day will need to be reprogrammed, so check the clock after any outage or after unplugging the unit to move it.
Q8: Why didn't the alarm go off right away?
Ans: Zoo Med builds in delays: the alarm is delayed by 30 minutes when power is first turned on and when switching between day and night periods, and the Socket 3 humidity alarm has a 40-second delay before it triggers.
Q9: How do I switch between Fahrenheit and Celsius?
Ans: Press and hold the up and down arrow buttons at the same time for 6 seconds. To temporarily silence a beeping alarm, press any button or hold the power button and the down arrow for 6 seconds to mute all keypad and alarm tones.